12010 Haven Crest Street,Moorpark, CA, US

Install **A TECHNICIAN WILL BE ONSITE TO ADJUST FURNACE FOR UPSTAIRS SYSTEM. Had to order an 80k furnace, needs to be adjusted for a 3-ton application.

Sales- Kevin McNerney

Turn- N/A

D/S - Upflow furnace, coil, A/C, ducting (approx 8 runs total for job)

U/S- Horizontal furnace, coil, A/C, ducting

Total- $25,000.00 (CC or check, sales did not specify)

  • HVAC
  • HVAC: HVAC Install
  • Price Ranges
  • Price Ranges: 20001 - 25000
  • Date Ranges
  • Date Ranges: 2020 - Q3

2291 Solano Drive,Camarillo, CA, US

Sales: Jeff

SCOPE OF WORK (Local & California Plumbing Codes included for reference):

 - Installation of new water heater at existing water heater location.

 - Connect existing exhaust vent to water heater vent hood; ensure vent is supported, if needed, and all vent connections are fastened w/ 3 vent screws (CPC 503.3) *Price is subject to change if additional materials/modifications are required*

 - Installation of a new brass water shut off valve on the cold-water line (if needed) (CPC 606.2)

 - Installation of new 1” dielectric stainless steel flexible connectors on the cold & hot water lines.

 - Insulate up to 5ft of the cold & hot water lines (not required in a conditioned space) (150 (J) 2)

 - Installation of a 4.4 gal. thermal expansion tank; secured/fixed to wall (CPC 608.2 & 3)

 - Installation of brass electrical bonding clamps on the cold-water line, hot water line & gas line, connecting all 3 brass bonding clamps using 6-gauge copper wire to aid in the prevention of electrolysis (not required on PEX plumbing systems) (EC 250-104 a,b)

 - Installation of uni-strut system & seismic straps (upper, middle & lower) to prevent horizontal displacement in the event of an earthquake (CPC 507.2)

 - Installation of a new temperature & pressure relief valve (CPC 608.5)

 - Connect to existing drain line for temperature and pressure relief drain; ensure drain line is terminating at an approved location (CPC 608.5) *Price is subject to change if additional materials/modifications are required*

 - Installation of a new 1/2” brass gas shut off valve, 1/2” gas sediment/debris trap & 1/2” x 24” flexible powder coated stainless steel gas connector (CPC 1211.5 / 1212.8)

 - Installation of an aluminum drain pan beneath water heater (CPC 507.5) - Installation of up to 5ft of 3/4” PVC drain line from the aluminum drain pan to an approved location (CPC 507.5) *Price is subject to change if additional materials/modifications are required*

 - Cover existing water heater stand w/ sheet metal & angle iron (if applicable)Collect: $5,818.00

Confirmed with Harry 304-550-0933 who will be on site 04/08, after 12:00

Install a 2 1/2” horizontal earthquake valve, Install 1” Moen Flo auto leak device. ( no regulator on system), Install clean out plugs, Rebuild cottage toilet, back guest toilet and front guest toiletSold by Bill

**UPON COMPLETION, PLEASE COLLECT $6,519.91**

Please call when on the way 304-550-0933

Install Noritz NRC98OD TanklessSold by Bill

**UPON COMPLETION, PLEASE COLLECT $11,006.45**

PLEASE CALL WHEN ON THE WAY 304-550-0933


Install

Sales- Jesse

Turn- Dan

System 1- Horizontal R802VA furnace, coil, RA16 A/C + (10 runs)

System 2- 10 runs + some additional runs ***TOTAL OF RUNS 26-27***

**Returning at a later date for insulation.

Total - $41,116.00 (CC or check; Sales did not specify)


Sales - Jesse C

Tech - Parker

3TON horizontal RH2T air handler, BOVA15 A/C, Total due - $17,000.00 (Collect CC or check)

ELECTRICAL- Running #8 wire approximately 50 ft for a new 240 volt from panel to attic.


Installation **Waiting on pre for system sizing.

Sales- Jesse

Turn- N/A

Bedroom System- Horizontal R802VA furnace/coil in attic, BOVB18 A/C, *DO NOT SETUP FOR DUAL FUEL!*Total due - $17,900.00 *Collect Check*

**THIS IS A TWO DAY PROJECT

Sales- Jesse C

Turn-

Installing approximately 5,320 sq. ft. of blow-in insulation over existing to R38 value.ALSO- will be installing approximately 2,500 sq. ft. of R38 blow-in in back bedroom.Total due today $2,500.00

  • Plumbing
  • Plumbing: Plumbing Install
  • Price Ranges
  • Price Ranges: -10000
  • Date Ranges
  • Date Ranges: 2024 - Q3
  • Plumbing: Water Heater Install
  • Date Ranges: 2025 - Q2
  • Price Ranges: 10000 - 15000
  • Date Ranges: 2024 - Q4
  • HVAC
  • HVAC: HVAC Install
  • Date Ranges: 2022 - Q3
  • Price Ranges: 15001 - 20000
  • Date Ranges: 2024 - Q1
  • Price Ranges: 40001 - 45000