Charlene Skinner, CA

1 of 2: Eber, break away to do pressure regulator. Mark yourself as done on this job, clock into regulator job, complete job once done and clock back into re-pipe job. Sales: PaulReplace old pipes with pex under the home. To the copper drops to each fixture.

The shower, the bathtub, the lav. And the toilet. Of the extension at the back of the home.

These pipes will be insulated and strapped.

Five-year warranty on parts and labor.Collect: $4,389.00

Confirmed with Charlene 818-521-1612 who will be on site 03/06


Install **PRE 8AM

Sales- Greg

Turn- Jesse

Mobile home AC XR-14

Deposit: $590.00 (check)

Total due: $5,310.00 (VISA)


Install

Sales- Kevin McNerney

Turn- Ryan Peck

Mobile home furnace, coil, A/C

Deposit: $1,000.00 (check)

Total due $7,900.00 *Marisa to call homeowner for CC; tenant situation

Installation

Sales- Brice

Turn- N/AAdd on (2) head bosch mini split system.Total - $12,000.00 (CC or CHECK)

Install

Sales- Greg

Turn- N/A

Maytag downflow furnace, coil, roof jack, XR-14

Total - $10,636.00 - Wells Fargo 18 months no interest

Sales- DerekPLease upload pic to acct or send to Krista for warranty

40-Gallon Mobile Home Water Heater Replacement

Replacement of an existing 40-gallon gas water heater in a mobile home closet with no recirculation pump.

Location: Outdoor Closet

Recirculation Pump: No

Tasks:

Preparation and Shutoff:

1. Shut off gas supply valve

2. Close main water supply

3. Drain existing water heater to empty tank


Removal of Existing Unit:

1. Disconnect gas line from heater

2. Detach cold and hot water supply lines

3. Remove and dispose of old unit per local regulations


New Water Heater Installation:

1. Position new 40-gallon mobile home unit with adequate clearance per code

2. Install new drain pan beneath unit (if space allows)

3. Connect new stainless steel water supply lines (cold and hot)

4. Install 1/4-turn ball valve on cold water inlet

5. Install expansion tank, adjusted to home water pressure (typically 50-60 PSI)

6. Fit new gas shutoff valve on gas line

7. Attach new flexible gas supply line with sediment trap

8. Secure unit with mounting brackets suitable for mobile home

9. Reconnect to existing T&P relief valve exit point

10. Insulate water supply lines for efficiency

11. Install copper bonding wire from water lines to gas line for grounding

12. Cover base/stand with sheet metal for protection


Venting and Combustion:

1. Install venting per manufacturer’s specs (e.g., double-wall or single-wall as required)

2. Secure single-wall vent connections with 3 screws each

3. Verify adequate combustion air supply per code


Testing and Startup:

1. Pressure-test gas and water connections for leaks

2. Fill tank and purge air from lines

3. Test T&P relief valve operation

4. Light pilot, set temperature to 120°F (or per client preference), and confirm burner ignition

5. Validate full operational status


Cleanup and Final Steps:

1. Clear debris from work area

2. Haul away old unit for disposal

3. Conduct final inspection with client walkthrough


Notes:

- Estimate valid for 60 days from issuance

- Includes permit fees (if required)

- Unforeseen issues or additional work will be quoted separately with client approval

- Exclusions: Drywall, paint, stucco, tile, concrete, stone repairs, or existing water damage

- Duration: 3-4 hours, 1 technician

- Warranty: Manufacturer - 6 years parts, 1 year labor; Conejo - 3 years labor

- Financing: 18 months at 0% interest available

- Qualifies for applicable utility rebates and federal tax credits (where available)CC or check $3311.20

  • Date Ranges
  • Date Ranges: 2025 - Q4
  • HVAC
  • Price Ranges
  • Price Ranges: -10000
  • Plumbing
  • Plumbing: Plumbing Install
  • Date Ranges: 2025 - Q1
  • HVAC: HVAC Install
  • Price Ranges: 10000 - 15000
  • Date Ranges: 2025 - Q3
  • Date Ranges: 2022 - Q2
  • Date Ranges: 2020 - Q3
  • Date Ranges: 2021 - Q3
Lisa Brasher - $10900 - 4/1/21, CA

Install **MUST HAVE HOMEOWNER SIGN FINANCING FORM AND BRING BACK TO OFFICE. VERY IMPORTANT - THANK YOU

Sales- Kevin

Turn- N/A

Mobile home downflow Coleman furnace, coil, add on RA14 condenser.

Total - $10,900.00 *Customer is financing; Synchrony 18 months*

  • HVAC
  • HVAC: HVAC Install
  • Price Ranges
  • Price Ranges: 10000 - 15000
  • Date Ranges
  • Date Ranges: 2021 - Q2
Nickie Kubasak - $28500 - 12/8/21, CA

Install

Sales- Kevin McNerney

Turn- N/A

50 gallon water heater, comfort pump, and 2 safety floats.

Total - $3,650.0 (check)


Install

Sales- Greg

Turn- Georgie fimbres

(2) BOVB18 A/C's; Moving 1 A/C to opposite side of house in front of fireplace/moving line set/moving 240.

Total - $28,500.00

$25,200.00*FINANCING; Synchrony 18 months*

$3,300.00 Collect CC

  • HVAC
  • HVAC: HVAC Install
  • Price Ranges
  • Price Ranges: 25001 - 30000
  • Date Ranges
  • Date Ranges: 2021 - Q4
  • Price Ranges: -10000
  • Date Ranges: 2020 - Q1
Susan Allen - $14810 - 3/14/23, CA

Installation | **7AM PRE | 8:00AM SHARP START TIME

Sales- Greg

Turn- Jesse Murillo

3TON/60K Upflow Ruud R802VA, coil, BOVA15 A/C

Total - $14,810.00 *Synchrony 18 months no interest*

  • HVAC
  • HVAC: HVAC Install
  • Price Ranges
  • Price Ranges: 10000 - 15000
  • Date Ranges
  • Date Ranges: 2023 - Q1
Jeffrey Lee an Terri Nguyen - $10500 - 11/12/20, CA

Install

Sales- Greg Jamroz

Turn- N/A

Upflow furnace, coil, A/C

Deposit: $1,000.00 (CC)

Total due: $9,500.00 (CC)

  • HVAC
  • HVAC: HVAC Install
  • Price Ranges
  • Price Ranges: 10000 - 15000
  • Date Ranges
  • Date Ranges: 2020 - Q4