Conejo Services - Internal Map
We service the Ventura, Los Angeles, and Santa Barbara Counties and surrounding areas. Reach out to us if you’d like a consultation, (805) 232-5559
Our Work
Laura Bintliff, CA
Insulation **TWO DAY PROJECT
Sales- Greg
Turn- Juan G
Remove approx. 2,000 sq. ft. of BATT insulation.
Install approx. 2,000 sq. ft. of blown-in insulation to R38 value
Total due - $8,800.00 (CC or CHECK)
- Date Ranges
- Date Ranges: 2025 - Q4
- Roofing
- Price Ranges
- Price Ranges: -10000
Katie Schlossmann, CA
Sales-Nick S.**Send Krista water heater label or upload to acct**
PROPOSED WATER HEATER INFORMATION:
• Brand: Noritz
• Model: NRCR 111
• Serial: ***serial***
• BTU/hour Input: 18,000 - 199,000
• Energy Star: Yes
• Uniform Energy Factor: 0.97
• Energy guide estimated annual operating cost: $193
• GPM at 45°F temperature rise: 7.6
• Minimum flow to activate: 0.5gpm
• Number of showers at one time: 1 - 4
SCOPE OF WORK (California Plumbing Codes (CPC) included for reference):
• Installation of new tankless water heater.
• Installation of 2” or 3” PVC exhaust vent to an approved location (CPC 701 - 705/503.2 & 503.3)
• Installation of a new shut off valve on the cold water line (CPC 606.2)
• Installation of isolation valves on the tankless water heater for future servicing.
• Installation of new 3/4” dielectric stainless steel flexible connectors on the cold & hot water lines.
• Insulate up to 5ft of the cold & hot water lines (150 (J) 2)
• Installation of a thermal expansion tank (CPC 608.2 & 3)
• Installation of electrical bonding clamps on the cold water line, hot water line & gas line, connecting all 3 using 6 gauge copper wire to aid in the prevention of electrolysis (250-104 a,b)
• Installation of uni-strut; mounting the tankless water heater to the proposed location
• Installation of pressure relief valve with a 3/4” copper drain line ran to an approved location (CPC 608.5)
• Installation of a new 3/4” gas shut off valve, gas sediment trap & 3/4” x 24” flexible gas connector to water heater (CPC 702/1212.9)
• Installation of a condensate neutralizer (CPC 307)
• Installation of a 3/4” PVC condensate drain line to an approved location (CPC 307)
• Installation of Noritz control panel at water heaters location for future diagnostic purposes.
• Cover existing water heater stand w/ sheet metal & corner caps (if applicable).
WARRANTY INFORMATION:
• Conejo Plumbing & Rooter: 3 years for parts & labor.
• Manufacturer warranty:
- 1 year labor
- 5 years parts
- *15 years replacement on heat exchanger when the product is used for a single family dwelling (with pre-heated or circulated water).
- **25 years replacement on the Heat Exchanger when used in a single family dwelling (without pre-heated or circulated water).
NOTE: Warranty starts on the date of proper Installation of the product, or 30 days after the date of purchase of the product, whichever occurs first, and is effective until the expiration of the “Warranty Period” for the particular product component.
* An aquastat is the minimum pump control requirement in order to maintain the full recirculation warranty. Point of use or “on demand” recirculation systems which are thermally controlled (i.e. aquastat) also classify as controlled systems. Residential recirculation warranty – 15 years or 12,000 operational (burn) hours as recorded by Noritz Product, whichever occurs first.
** 25 years or 15,000 operational (burn) hours as recorded by the Noritz Product, whichever occurs first.
FINANCING OPTIONS:
• 18 months 0% financing no terms is available.
DISCLAIMER:
• Conejo - Plumbing Division is not responsible for the repair or replace of drywall, paint, stucco/plaster, carpet/flooring, or existing water damage. All such repairs & replacements are the sole responsibility of the property owner/property manager.
• For any projects requiring specialized licensing and/or qualifications, Conejo Services is able to provide estimates for the following divisions:
- Plumbing
- HVAC
- Insulation
- Electrical
- Roofing
Please note that all work must be performed by qualified professionals to comply with safety requirements, local regulations & company/industry standards.
• All estimates & proposals provided by Conejo - Plumbing Division are valid for a period of six months from the date of issuance. After this period, any estimates or proposals are subject to change based on market conditions and pricing. It is recommended to review and confirm any estimates or proposals with Conejo - Plumbing Division if more than six months has passed since the date of issuance.
CC or Check $8450.00
- Date Ranges
- Date Ranges: 2025 - Q4
- Roofing
- Roofing: Roof Services
- Price Ranges
- Price Ranges: -10000
Susan Kirch, CA
Install
Sales- Owen
Panel upgrade to 200amp (overground) + We will be fixing the wiring in the garage due to exposed fishscale romex. Only the wiring that is exposed is getting reran, anything in conduit is good to stay. There is also an extension used to power a motion sensor flood light that will get re ran.
Total due - $7,620.00 (CC OR CHECK)
- Date Ranges
- Date Ranges: 2025 - Q4
- Roofing
- Price Ranges
- Price Ranges: -10000
Nicole Ellis, CA
Installation
Sales- Brice
Turn- N/A
5TON horizontal R801 furnace/coil, Innovair square A/C, 50 gallon water heater, NUVE thermostat.
TOTAL FOR THIS PORTION - $15,858.00**NOTES FOR ACCOUNTING ON PAYMENT: FINANCE - $14,258.00 *Synchrony 132/9.99%*COLLECT CHECK - $5,000.00**
Sales- Brice Daly**Send Krista water heater label or upload to acct**
Turn- N/A50 gallon water heater replacementTotal for this portion - $3,400.00 **NOTES FOR ACCOUNTING ON PAYMENT: FINANCE - $14,258.00 *Synchrony 132/9.99%*COLLECT CHECK - $5,000.00**
- Date Ranges
- Date Ranges: 2025 - Q4
- Roofing
- Price Ranges
- Price Ranges: 15001 - 20000
- Price Ranges: -10000
David Galvin, CA
Sales- Tony**Little Kevin to come and help you**Call tony for details**Slab Leak Reroute
Reroute water lines to bypass a slab leak in a residential or commercial property, avoiding costly and invasive slab excavation while restoring water system functionality and preventing further damage. Slab leaks, often caused by pipe corrosion or ground movement, can lead to water loss, high utility bills, and structural issues like foundation cracks or mold. This process involves identifying the leak with electronic detection, isolating the affected pipe, and installing new copper or PEX piping through alternative routes (e.g., walls, ceilings, or crawlspaces) to restore water flow. The reroute eliminates the need to repair the slab-embedded pipe, offering a cost-effective and less disruptive solution. Note that Conejo does not repair or replace drywall, paint, or stucco, so any wall penetrations or cosmetic repairs must be handled by the client or a separate contractor.
Location: Interior/Exterior (Alternate Routing Path)
Tasks:
Preparation:
1. Locate slab leak using electronic leak detection equipment (e.g., acoustic or infrared tools).
2. Shut off main water supply and isolate affected piping to prevent water loss.
3. Plan reroute path (e.g., through walls, attic, or crawlspace) and set up work area with tools (pipe cutter, fittings, PPE).
Pipe Rerouting:
1. Install new copper or PEX piping along the planned reroute path, avoiding the slab leak.
2. Connect new line to existing water supply and fixtures using appropriate fittings (e.g., tees, couplings).
3. Secure piping with hangers or clips every 4-6 feet to prevent movement, per code.
System Integration:
1. Cap or isolate the leaking slab pipe to prevent future use, ensuring no pressure loss.
2. Integrate new piping with existing system, maintaining water pressure (40-80 psi).
3. Ensure rerouted lines are accessible for future maintenance and avoid structural obstructions.
Testing:
1. Restore water supply and perform pressure test to confirm no leaks in rerouted lines.
2. Run water through fixtures to verify normal flow and no cold water mixing.
3. Inspect all connections for leaks using a pressure test or visual inspection.
Cleanup and Final Steps:
1. Clean work area and dispose of debris per local regulations.
2. Provide client with reroute layout and maintenance instructions.
3. Conduct walkthrough to demonstrate restored water flow and explain limitations.
Notes:
- Bypasses slab leaks to restore water flow without invasive slab excavation.
- Conejo does not repair or replace drywall, paint, or stucco; client responsible for cosmetic repairs.
- Additional piping or complex rerouting quoted separately if needed.
- Advise client to monitor water bills and new piping for signs of leaks.
- Estimate valid for 60 days from issuance
- Includes permit fees (if required)
- Unforeseen issues or additional work will be quoted separately with client approval
- Exclusions: Drywall, paint, stucco, tile, concrete, stone repairs, or existing water damage
- Duration: 6-8 hours, 2 technicians
- Warranty: 5 years parts, 2 years labor
- Financing: 18 months at 0% interest available
CC or Check $2789.00
- Date Ranges
- Date Ranges: 2025 - Q4
- Roofing
- Price Ranges
- Price Ranges: -10000
Customer Testimonials